WATER RECOVERY REVERSE OSMOSIS SPECIALIST

 

 

CTR-6 DESIGN CONDITIONS

 

Type BW4040-6m fresh water generator
  • Principle : Reverse Osmosis (R/O)
  • Capacity : 42,055 LPD/24hr. Total recovery ratio: 40-70 %
  • Salt rejection: 99 %
  • Power supply: 380v/50Hz/three/phase
  • Installed power: 5.5 hp
  • Operating pressure: 170 to 210 psi
  • Design temperature : 25 Degr. Celsius

Feedwater Data

  • Salinity: 2000 ppm/TDS
  • Maximum temperature: 40 Degr. Celsius
  • Flow: 2,380 LP/hr.
  • SDI: < 3
  • PH range: 2-11
  • Iron (Fe): < .1 mg/l
  • Free chlorine: < .1 mg/l
  • Max: feed turbidity: less than 1 NTU
  • Feed water pressure: 30-60 psi at inlet of unit

The feedwater must be free of Fe3 and bacterial contaminations. The feedwater piping must be made of non-corrosive materials, such as PVC, stainless steel 316 etc.

Weight: 450 Kgs. Dry

Dimensions: Height: 1.3 m Length: 3.5. m Width: 1.0 m

 

 

ADDRESS

30/4  M.4 Nongplalai Banglamung
Chonburi 20150 Thailand

Telephone: 66-38-424-266, 89-407-2228

Fax: 66-38-716-450, 427-206

Mobile: 66-81-344-9296, 81-835-4908