WATER RECOVERY REVERSE OSMOSIS SPECIALIST

 

 

TRO-2,000 DESIGN CONDITIONS

 

Type BW4040-ACM3-1m fresh water generator
  • Principle: Reverse Osmosis (R/O)
  • Capacity: 7,570 LPD/24hr.
  • Total recovery ratio: 30-65 %
  • Salt rejection: 99-99.5 %
  • Power supply: 380v/50Hz/three/phase
  • Installed power : 3 hp
  • Operating pressure: 150 to 210 psi
  • Design temperature: 25 Degrees Celsius

Feedwater Data

  • Salinity: 500 PPM/TDS
  • Maximum temperature: 40 Degrees Celsius
  • Flow: 1,577 LP/hr.
  • SDI: < 3
  • PH range: 2-11
  • Iron (Fe): < .1 mg/l
  • Free chlorine: < .1 mg/l
  • Max: feed turbidity: less than 1 NTU
  • Feed water pressure: 30-60 psi at inlet of unit

The feedwater must be free of Fe3 and bacterial contaminations. The feedwater piping must be made of non-corrosive materials, such as PVC, stainless steel 316 etc..

Weight: 105 Kgs. Dry

Dimensions: Height: 1.32 m Length: .89 m Width: .66 m

 

 

If you need more information about our products E-mail or call us today

K&N Thailand Co., LTD.

30/4 M.4 Nonplalai  Banglamung Chonburi 20150 Thailand.

Tel: 66- 38-424-266, 89-407-2228 Fax: 66-38-716-450, 427-206 Mobile : 66-81-344-9296, 81-835-4908
 

E-Mail : knrothai@loxinfo.co.th